• -13%
Alarm Squealer - 3 Triple GSM for separators

Alarm Squealer - 3 Triple GSM for separators

PLN6,362.79 13%
PLN5,535.63 tax incl
PLN4,500.51 tax excl

Lowest price in the period of 30 days before current promotion: PLN5,535.63 0%

SQU-3-GSM
Probe:
Lead time 7-14 days
Ask about the product
  • 3-probe detector
  • Three probes to choose from: (MAX) overfill, (OILER) level, (SLUDO) sludge level
  • GSM version, battery version, 230 V version

SQUEALER-3 alarm detector

Modern, microprocessor-based device for continuous monitoring of liquid overflow status, oil level, sludge level thanks to the connection of 3 probes (MAX, OILER, SLUDO)

The composition of the SQUEALER-3 set

SQUEALER-3 detector equipped with 3 inputs + 3 outputs with probes:

  • MAX (overfill probe)
  • OILER (oil, fat, petroleum level probe)
  • SLUDO (sludge probe)
  • 3 x Power supply intrinsically safe cable 2 x 0,75 mm2 for sensors 5 linear meter (CABLE-5 - extending standard probe cables)
  • 3 x Set for hanging sensors for plastic tanks (NFIX-02)
  • 3 x connection coupler - used when the cable has to be extended, the coupler is used to connect them in an airtight manner (COUPLER-01)
The composition of the SQUEALER-3-WRL set

SQUEALER-3 detector equipped with 3 inputs + 2 outputs with probes:

  • MAX (overfill probe)
  • OILER (oil, fat, petroleum level probe)
  • SLUDO (sludge probe)
  • GSM (SMS, system status on request, battery status notification)
  • 3 x Power supply intrinsically safe cable 2 x 0,75 mm2 for sensors 5 linear meter (CABLE-5 - extending standard probe cables)
  • 3 x Set for hanging sensors for plastic tanks (NFIX-02)
  • 3 x connection coupler - used when the cable has to be extended, the coupler is used to connect them in an airtight manner (COUPLER-01)
The composition of the SQUEALER-3-WRL-GSM set

The SQUEALER-3 detector is equipped with 3 inputs + 1 output with probes:

  • MAX (overfill probe)
  • OILER (oil, fat, petroleum level probe)
  • SLUDO (sludge probe)
  • GSM (SMS, system status on request, battery status notification)
  • Battery powered (up to 2 years battery life) or solar panels
Technical data

  • Power supply: 230V AC
  • Max. fuse: 1.25 A
  • Power consumption (nominal): 2.2 VA
  • Relay outputs REL1, REL2, REL3: Potential-free NO or NC contacts, 2A / 120V AC or 2A / 24V DC
  • Ambient temperature: -40 to + 60 ° C
  • Mechanical strength: IK 07
  • Housing dimensions (without cable glands) (H x W x D): 187 x 122 x 90 mm
Probes in the set

  • Overflow probe
Hang the probe with a 5 m standard cable on the FIX holder, which should be placed directly under the hatch - preferably in the inspection hole in the separator cover.

 
  • Petroleum / organic oil level probe
The probe should be placed at the appropriate depth / height and the sensor cable should be wound around the mounting eye (FIX) in such a way that the cable is blocked and the probe does not change its position on the handle during operation.

 
  • Sludge level probe
The mounting height of the sensor depends on the volume of the device's sedimentary part. The amount of accumulated sludge must not exceed 1/3 ÷ 1/2 of the height between the bottom of the outlet pipe and the bottom of the sludge chamber. When installing the sensor, it should be noted that usually sediment accumulates in the measurement zone at different heights, which depends primarily on the speed of flowing sewage. Where the flow velocity is lowest, it will accumulate the most and vice versa. Hang the probe with a 5 m standard cable on the holder. The handles should be placed directly under the hatch - preferably in the inspection hole in the separator lid.

Standard each probe is fitted with a 5 m cable.

Additional options

  • It is possible to extend the power cable (intrinsically safe cable 2 X 0.75 mm2 for sensors) (CABLE-10),
  • A set for hanging probes in concrete tanks is also available (NFIX-01).
In our separator alarms category we have other models such as: TWIN SEPARATOR ALARM andBASIC SEPARATOR ALARM

ADDITIONAL NOTES

There is no power cable included with the Squealer detector (not to be confused with the CABLE-5). You must supply the cable to the device yourself.