- -5%
Home and garden set Standard Octagon 7500l
PLN26,267.00
5%
PLN24,953.65
tax incl
PLN20,287.52
tax excl
Lowest price in the period of 30 days before current promotion: PLN24,977.40 0%
ZWDS0023
- Flat tank capacity from 4,000 l to 11,000 l
- Rainwater supply to WCs, urinals, washing machines and garden outlets
- Rainwater management system with rainwater control panel
Home and garden set Standard Octagon
System for rainwater management in the house and garden using a rainwater control panel
Rainwater is collected from the roof via a gutter system and fed through a drain pipe into the tank. The water is cleaned in a fine-mesh Maxi filter and then flows into the tank (by gravity). A pump pumps the water from the tank to the building's sanitary devices (e.g. toilet cistern, washing machine). If the water level in the tank is too low, the sanitary facilities are automatically supplied with tap water. The house-garden system is equipped with a control panel with self-priming pump and tap water make-up control. The distance between the house and the tank can be a maximum of 12 m. This is associated with excessive suction line losses due to the large height difference between the bottom of the tank and the control panel and/or the distance between the tank and the control panel. A booster pump should then be used for the system.
Delivery range
- Installation in difficult ground and water conditions is permissible (according to the rules of installation instructions)
- Low height - shallower excavation, less earthworks
- Flat, robust tank construction
- It can be buried up to 1.5 m (ground level)
- Low weight, simple installation
- It can be loaded with traffic when properly equipped for vehicle traffic
- It is made of monolithic pure polyethylene
- 3 connections ø110 mm and inspection hole DN600 in each tank.
- Dedicated place for making the spigot for the battery connection
Technical dimensions
Capacity [l] | Lenght [mm] | Width [mm] | Casing height [mm] | Height with flange [mm] | Inspection hatch | Przyłącza | Mass [kg] |
4 000 | 2450 | 2450 | 1075 | 1375 | DN 600 | 3x DN 110 | 155 |
7 500 | 4480 | 2450 | 1075 | 1375 | DN 600 | 3x DN 110 | 305 |
11 000 | 6510 | 2450 | 1075 | 1375 | DN 600 | 3x DN 110 | 455 |
Tank cover - TopCover with gasket + Ascending pipe extension VS 60
Tank cover designed for pedestrian traffic. It is made of double-wall polyethylene and has a child safety device. A compatible gasket is included with the lid. The VS 60 ascending pipe extension is 635 mm high, Ø 600 mm.
Maxi filter with extension |
Filter basket including ascending (extension) pipe to be fitted to the filter. (Dimensions: Ø 350 mm, height 570 mm. Possibility of freely shortening the overlay). The rainwater filter basket is equipped with a convenient handle for pulling the basket out. It is excellent for use in gardens, ponds and drainage systems. The rainwater filter ensures thorough cleaning thanks to its 0.9 mm mesh size and is therefore also suitable for domestic systems. It is installed directly in the ground in front of a tank or rainwater infiltration system. Advantages include : Narrow design, simple installation, small cover. Inlet and outlet DN100. Housing and cover are made of rigid PE. There is an option for upgrade (with ascending pipe). Optional cover to allow vehicular traffic. Recommended for roof areas of up to 350 m². |
Sealed pipe DN100
They are used to seal the technical duct in which the cables and pump suction hose are routed.
Floating water intake
Thanks to the float, the intake always floats approx. 15-20 cm below the water surface, from where it is possible to pump the cleanest water from the tank (impurities of various kinds may float on the water surface). A mesh filter provides additional protection against impurities. Elements of the set: float with a diameter of 15 cm, mesh filter - mesh 1.2 mm, non-return valve 1``, spigot 1`` with o-ring for suction hose Ø 36 mm, suction hose Ø 36 mm and length 2 m.
House filter for 1`" water after rainwater control panel
Pipe filter with a diameter of 1`` for the treatment of rainwater from micro-pollutants.
Rainwater control panel:
The device pumps rainwater from the tank and delivers it to the indoor installation. If there is no rainwater in the tank, the control panel allows the automatic use of tap water. There are three main components in one device: pump, control and tap water make-up system. The control unit should be installed inside the house, e.g. in the basement, boiler room or utility room. For more information on the parameters of the C Plus rainwater control panels, please see the attachments.
Technical data | Rainwater control panel AquaMatic Domestic C Plus |
Max. capacity | 4,8 m3/h |
Max. pressure | 5,2 bar |
Max. distance to receiver | 15 m |
Max. suction depth | 8 m |
Protection class | IP 41 |
Rated power | 880 W |
Supply voltage | 230 V |
Suction line connection | 1`` (Female thread) |
Pressure pipe connection | 1`` (Male thread) |
Connection of tap water | ¾`` (Male thread) |
Emergency overflow | Pipe ᴓ 75 m |
Float switch | 20 m (without grounding) |
Dimensions (W x H x D) | 500 × 650 × 240 mm |
Weight | 30 kg |
Casing | YES |
Additional functionality | Possibility to connect a booster pump to extend the distance from the control panel to the rainwater tank* |
* This is caused by suction line losses due to excessive height differences between the bottom of the tank and the control panel and/or the distance between the tank and the control panel.