Model | Power [kW] | Voltage [V] | Max. lift [m] | Max. capacity [l/min] | Type | Working pressure [bar] | Control |
PSI/WQV1
Pump: WQV 7-16-1.5 | 1,5 | 1~230 | 20 | 316 | shredder | up to 1.5 | - Start-up capacitor (in the pump)
- Pump thermal protection
- Start-up float (integrated in the pump)
- + overflow float
- Optical/acoustic alarm system indicating overfilling of the pumping station, powered by 12 V low current with type B protection
- Residual current protection
- Surface-mounted control cabinet IP65
- Type C protection
|
PSI/K1
Pump: KRAKEN 1800 DF | 1,8 | 25 | 350 | up to 2 | - Start-up capacitor (in the pump),
- Pump thermal protection,
- Start-up float (in the pump),
- Overfill float indicating exceeded
- alarm condition in the pumping station,
- Optical and acoustic alarm system informing of overflow in the pumping station powered by a low-current 12-volt type B protection,
- Residual current protection,
- Surface-mounted control cabinet IP65,
- Run-0-Manual switch,
- Phase loss and asymmetry sensor,
- Voltage reduction transformer for 12 V.
|
PSI/VOX1.5
Pump: VOX 50 | 1,5 | 16 | 600 | free passage 50 mm | up to 1.2 | - Start capacitor (in the pump) + thermal protection of the pump
- Start-up float (integrated in the pump) + overflow float
- Optical/acoustic alarm system indicating overfilling of the pumping station, powered by 12 V low current with type B protection
- Residual current protection
- Surface-mounted control cabinet IP65
- Type C protection
|
PSI/K3
Pump: KRAKEN 1800 DF | 1,8 | 3~400 | 25 | 350 | shredder | up to 2 | - Start-up float
- Overflow float to indicate exceeding of alarm condition in the pumping station
- Pump thermal protection
- Optical and acoustic alarm system informing about overfilling the pumping station, powered by a low-current 12 V safety device type B
- Residual current protection
- Surface-mounted control cabinet IP65
- Run-0-Manual switch
- Phase failure and asymmetry sensor
- Voltage reduction transformer up to 12 V
|
PSI/Gr1-09
Pump: Grix 32-2/090 M/G | 09 | 1~230 | 22 | 165 | up to 2 | - Start-up capacitor
- Pump thermal protection
- Start-up float (integrated in the pump)
- Overflow float
- Optical and acoustic alarm system indicating overfilling of the pumping station, powered by 12 V low current with type B protection
- Residual current protection
- Surface-mounted control cabinet IP65
- Protection type C
|
PSI/3CE4
Pump: Compatta EVO 4 T | 1,1 | 3~400 | 13 | 510 | free passage 50 mm | up to 1 | - Start-up float
- Overflow float to indicate exceeding of alarm condition in the pumping station
- Pump thermal protection
- Optical and acoustic alarm system indicating overfilling of the pumping station, powered by 12 V low current with type B protection
- Residual current protection
- Surface-mounted control cabinet IP65
- Run-0-Manual switch
- Phase failure and asymmetry sensor
- Voltage reduction transformer up to 12 V
|
PSI/Gr3-09
Pump: Grix 32-2/090 T | 0,9 | 22 | 165 | cutting blade | up to 2 |
PSI/UP3
Pump: UP 60-80 | 1,5 | 60 | 80 | shredder | up to 5 | - Start-up float
- Overflow float to indicate exceeding of alarm condition in the pumping station
- Pump thermal protection
- Optical and acoustic alarm system indicating overfilling of the pumping station, powered by a low-current 12 V safety device type B
- Residual current protection
- Surface-mounted control cabinet IP65
- Run-0-Manual switch
- Phase failure and asymmetry sensor
- Voltage reduction transformer up to 12 V
|
PSI/H3
Pump: HARPIA 1100 T | 1,1 | 110 | 50 | cutting blade | up to 6 |